Snack's 1967

Concepts of Lightning and Surge Protection

Lightning strokes, which total 200 kA or 300 kV, cause hazards for the equipment or location, so lightning protection is important for operation.

Why don't we focus on the first note in regards to what is lightning and why lightning protection is so important. Principle phenomenon behind lightning is that charges accumulated from the cloud and the earth are equal and opposite. This forms a non-uniform potential gradient surface in mid-air. In the event the gradient is larger compared to the potential of the surface, the breakdown occurs as well as a "streamer" flows from your cloud for the earth.

A primary stroke occurs when the lightning hits the ability systems directly that the immense potential can cause destruction of the equipment or the facility. In contrast, an indirect stroke is carried out in the lightning discharges from the proximity of the power line or from electrostatic discharge for the conductor due to the charged clouds.

The main power system elements requiring lightning protection are power feeds, alarm systems, telephone lines, data and control systems and RF cables.

Types of Lightning Protection. The rolling sphere way is utilized for identifying the actual keeping the lightning and surge protection devices at the equipment under operation.



Protection of the power line against direct strokes is via a ground wire or protector tube. The previous produces electrostatic screening, which is impacted by the capacitances of the cloud to line as well as the line to ground. Aforementioned forms an arc relating to the electrodes, causing gas deionisation.

Rooftop/Frame Protection. It really is interesting to remember that this building and rooftop frame or cladding is preferably metal than insulation type.

Installing a finial at the top of the ability tower must have the absolute minimum distance of just one.5 m higher than the highest antenna or lights. A real rooftop or building frame consists of reinforced steel for cover purpose.

Wooden towers without downconductors may cause a fireplace hazard, while they route the incoming charges to ground. In principal, for non-metallic roofs, proper downconductors ought to be installed at the appropriate location and height.

Device Protection. Antenna lightning protection emerges through spark gap, the gas discharge tube and quad-wavelength shorted stub. The very first method uses ball points in order that if a strike occurs, high potential forms between them along with the ground. The 2nd method causes gas deionisation through arc formation involving the electrodes. The very last method uses a coax transmission line across the transmission line to ensure that system bandwidth is narrow.

A lightning arrester is really a device offering lightning protection by regulating spark gaps. The device classification may cover anything from rod gap, horn gap and valve type to metal oxide lightning arresters.

Earthing and Bonding Solutions. Now let's talk of how earthing and bonding solutions for lightning protection should be afforded. Design for earth rods, terminals or clamps must be in a way to route the incoming transients to earth to minimise step and touch potentials. The geometric measurements chosen should abide by the IEEE and NFPA standards. Any earthing system really should have proper bonding, as ground potential rise can't be compensated. Again, the number of interconnects and spacing must be designed per the lightning standards.